HemoCue Glucose 201 DM System | Blood Glucose Analyzer

HemoCue Glucose 201 DM System | Blood Glucose Analyzer

HemoCue

The HemoCue® Glucose 201 DM System

The HemoCue® Glucose 201 DM System is a sophisticated solution designed to enhance glucose testing accuracy and efficiency in clinical settings. This advanced system not only offers all the reliable features of the HemoCue® Glucose 201 System but also integrates seamlessly with Laboratory or Hospital Information Systems (LIS/HIS) for superior data management.

With its touch-screen display, built-in barcode scanner, and robust connectivity options, the HemoCue® Glucose 201 DM System streamlines patient and quality control data management. It supports up to five analyzers through a docking solution and ensures compliance with CLIA regulations while facilitating precise and efficient diabetes diagnosis and monitoring.

Glucose 201 DM System


What Does the HemoCue® Glucose 201 DM System Test For?

The HemoCue® Glucose 201 DM System tests for blood glucose levels, providing precise and reliable measurements essential for diagnosing and managing diabetes. This system is specifically designed to support healthcare professionals in monitoring glucose levels, helping to identify patients at risk for diabetes and to manage existing conditions effectively. Its advanced features enable accurate testing and integration with laboratory information systems, ensuring seamless data management and compliance with clinical standards.


Four-Step Testing Process for the HemoCue® Glucose 201 DM System

  • Prepare the Test: Insert a glucose reagent test cartridge into the analyzer.
  • Collect the Sample: Use a lancet to obtain a blood sample and apply it to the test cartridge.
  • Process the Sample: The system automatically processes the sample and displays results on the touch-screen within seconds.
  • Document the Results: Review and record the glucose levels, which are stored in the system’s data management software for easy access.

201 DM Systems Components


Glucose 201 DM System Benefits

  • Results Within 1 Minute: Provides rapid feedback for timely patient care.
  • Automatic Transfer of Results: Minimizes manual entry errors and enhances data accuracy.
  • Reduced Manual Entry Errors: Improves overall accuracy by reducing the chance of human error.
  • Individually Wrapped Microcuvettes: Prevents contamination and ensures reliable testing.
  • Built-In Quality Control Self-Test: Ensures consistent performance and accuracy.
  • Customizable Automatic Prompts: Streamlines testing with prompts for patient and operator identification.

How to Clean the 201 DM System

Proper cleaning of the HemoCue® Hb 801 Analyzer is essential to maintain accurate results and ensure the longevity of the device. Follow these steps to clean the analyzer effectively:

  1. Turn Off the Analyzer: Before cleaning, ensure the analyzer is powered off and disconnected from any power source or USB connection.
  2. Exterior Cleaning: Use a soft, lint-free cloth slightly dampened with a mild detergent solution or a 70% isopropyl alcohol wipe to clean the exterior surfaces. Gently wipe down the device, avoiding excess moisture to prevent liquid from entering any openings.
  3. Cleaning the Cuvette Holder: Remove the cuvette holder from the analyzer according to the manufacturer's instructions. Clean it with a soft brush or a swab dipped in mild detergent or 70% isopropyl alcohol. Allow it to dry completely before reinserting it into the analyzer.
  4. Disinfecting the Cuvette Holder: If necessary, disinfect the cuvette holder with a suitable disinfectant, ensuring it is compatible with the materials used in the analyzer. Rinse with distilled water and allow it to air dry completely.
  5. Reassemble and Power On: Once all components are dry, reassemble the analyzer, reconnect it to the power source, and power it on. The device is now ready for use.

HemoCue® Glucose 201 DM System Specifications

Principle

 

Modified glucose dehydrogenase in which the total amount of glucose is measured at the end point photometrically

Calibration

 

Factory calibrated and traceable to ID GC-MS method, needs no further calibration and no coding

Testing

Sample Material

Capillary, venous or arterial whole blood

Testing

Sample Volume

Approximately 5 μL whole blood

Testing

Measuring Time

 40-240 seconds

Testing

Displayed Range

Plasma equivalent values: 0-24.6 mmol/L (0-444 mg/dL)

Analyzer

Dimensions

 6.7x3.66x1.97 in (170x93x50 mm)

Analyzer

Weight

0.77 lbs.  (350 g), with batteries installed

Temp Ranges

Analyzer Storage

32-122 °F (0-50 °C)

Temp Ranges

Microcuvette Storage

Below 46 °F (8 °C), incl. freezer.
Up to 3 days in room temperature.
One-month open-vial stability stored in refrigerator

Temp Ranges

Analyzer Operation

64-86 °F (18-30 °C)

Quality Control

 

Built-in self-test; one level liquid control required each day of use

Power

Cable

AC adapter via docking station

Power

Rechargable Batteries

Internal rechargeable Li-ion batteries

Interface

 

USB/LAN POCT1-A

CPT Codes

82947-QW
82950-QW
82951-QW
82952-QW