The HemoCue® Hb 801 System is a cutting-edge solution designed to deliver lab-quality hemoglobin results quickly and conveniently at the point of care. Building on 40 years of proven clinical performance, this innovative system combines ease of use with advanced connectivity options, ensuring fast and accurate results in less than one second. By streamlining workflows and maximizing patient interaction time, the HemoCue® Hb 801 System empowers healthcare professionals to provide the highest level of care with confidence and efficiency.

Hb 801 System


What Does the HemoCue® Hb 801 System Test For?

The HemoCue® Hb 801 System is specifically designed to measure hemoglobin levels in blood. Hemoglobin, a crucial protein in red blood cells, carries oxygen from the lungs to the rest of the body. Accurate hemoglobin testing is essential for diagnosing and monitoring conditions such as anemia, a common blood disorder where the body lacks sufficient healthy red blood cells. The Hb 801 System provides precise, lab-quality hemoglobin measurements at the point of care, enabling healthcare professionals to make informed decisions quickly and effectively.


Hb 801 System Key Features and Benefits

Lab-Quality Results in Less Than a Second

The Hb 801 System sets a new standard for point-of-care testing by delivering accurate hemoglobin results almost instantly, ensuring timely clinical decisions without sacrificing precision.

Durable Performance in Challenging Conditions

Designed to perform reliably even in environments with high temperatures and humidity, the Hb 801 System maintains accuracy in demanding climates.

User-Friendly Interface

The system features a large display with intuitive on-screen symbols, replacing confusing error codes with easy-to-understand icons, streamlining the testing process.

Innovative “Let-Go-Grip” Design

The unique “Let-go-grip” feature allows for effortless microcuvette insertion—just insert and let go for a seamless testing experience.

Flexible Connectivity Options

With both Bluetooth and USB cable connectivity, the Hb 801 System easily integrates into your workflow, providing flexible data management solutions.

Reagent-Free Microcuvettes with Enhanced Stability

The system’s larger, reagent-free microcuvettes not only improve handling but also offer superior open-vial stability, lasting up to 30 months for consistent and reliable testing.


Three-Step Testing Process with the Hb 801 System

Achieving lab-quality results with the Hb 801 System is as simple as three easy steps:

1. Fill the Microcuvette

Start by filling the microcuvette with a small blood sample.

2. Place the Microcuvette into the Analyzer

Insert the filled microcuvette into the analyzer using the system’s innovative “Let-go-grip” design.

3. View Results

In less than one second, the system provides accurate hemoglobin results on the large, easy-to-read display.


How to Clean the Hb 801 System Analyzer

Proper cleaning of the HemoCue® Hb 801 Analyzer is essential to maintain accurate results and ensure the longevity of the device. Follow these steps to clean the analyzer effectively:

  1. Turn Off the Analyzer: Before cleaning, ensure the analyzer is powered off and disconnected from any power source or USB connection.
  2. Exterior Cleaning: Use a soft, lint-free cloth slightly dampened with a mild detergent solution or a 70% isopropyl alcohol wipe to clean the exterior surfaces. Gently wipe down the device, avoiding excess moisture to prevent liquid from entering any openings.
  3. Cleaning the Cuvette Holder: Remove the cuvette holder from the analyzer according to the manufacturer's instructions. Clean it with a soft brush or a swab dipped in mild detergent or 70% isopropyl alcohol. Allow it to dry completely before reinserting it into the analyzer.
  4. Disinfecting the Cuvette Holder: If necessary, disinfect the cuvette holder with a suitable disinfectant, ensuring it is compatible with the materials used in the analyzer. Rinse with distilled water and allow it to air dry completely.
  5. Reassemble and Power On: Once all components are dry, reassemble the analyzer, reconnect it to the power source, and power it on. The device is now ready for use.

HemoCue® Hb 801 System Product Specifications

Principle

Measure absorbance of whole blood at an Hb/HbO2 isosbestic point (506 and 880 nm)

Calibration

Factory calibrated against the ICSH reference method; needs no further calibration

Sample Material

Capillary or venous whole blood

Measurement Range

1.0-25.6 g/dL

Results

< 1 second

Sample Volume

10 μL

Storage Temperature

Analyzer: 32-122°F (0-50°C)
Microcuvettes: 50-104°F (10-40°C)

Operating Temperature

50-104°F (10-40°C)

Power

USB adapter or 3 AA batteries (1.5 V Alkaline or 1.2 V NiMH)
Optional: HemoCue® rechargeable battery

Interface

USB and Bluetooth

Quality Control

Built-in self-test; optional liquid controls

CPT Code

85018-QW
The CPT codes provided are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payer being billed.

Prop 65 Warning

Warning: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

 